Chapa de Aço MUNICH boiler

With powers from 70 to 2907kw, designed for domestic hot water production, central heating, swimming pool heating and other industrial applications. Prepared to work with different fuels such as Natural Gas, LPG, Diesel or Pellets.

Drilling the boiler door to fit the burner costs extra.

Optional: ZQCA 2.0 control panel (you will need a GAS / GASOLEO control panel)

Ficha técnica do produto
Código Modelo Preço (s/IVA) Disponibilidade Comprar
0104-0201 Munich 70 Industrial Boiler
0104-0202 Industrial Boiler Munich 93
0104-0203 Industrial Boiler Munich 116
0104-0204 Munich 151 Industrial Boiler
0104-0205 Munich 186 Industrial Boiler
0104-0206 Munich 232 Industrial Boiler
0104-0207 Munich 290 Industrial Boiler
0104-0208 Munich 372 Industrial Boiler
0104-0209 Munich 465 Industrial Boiler
0104-0210 Industrial Boiler Munich 581
0104-0211 Munich 744 Industrial Boiler
0104-0212 Munich 930 Industrial Boiler
0104-0213 Industrial Boiler Munich 1162
0104-0214 Industrial Boiler Munich 1453
0104-0215 Munich 1860 Industrial Boiler
0104-0216 Industrial Boiler Munich 2325
0104-0217 Industrial Boiler Munich 2907
1706-0156 Quadro de Controle Analogico ZQCA 2.0 (GÁS / GASOLEO)

Principais Características


- Max. hot water outlet temperature: 90ºC;
- Operating pressure: max. 4 or 6bar.
- High quality sheet steel construction;
- ZQCA 2.0 control panel (not included)
- Can work with diesel or gas burners with 1, 2 or modulating flames or pellet burners.
- Door with plate for fixing the burner. The plate does not include drilling. Cost not included.

Especificações Técnicas


Technical dice 70 93 116 151 186 232 290 372 465 581 744 930 1162 1453 1860 2325 2907
Useful thermal power (kW) 80 93 116 151 186 232 290 372 465 581 744 930 1162 1453 1860 2325 2907
Yield (%) 93,9 93 92,5 92,6 92,7 92,8 92,3 91,5 90,6 90,5 90,3 90,1 91 92 93,5 93,8 94,1
Pressure loss gases (mbar) 0,2 0,6 1 1,1 1,2 1,6 1,8 2 2,5 3,2 4,4 5,4 6,2 6,7 7 9 12
Water pressure drop (mbar) 10 10 10 10 10 10 15 20 25 30 35 38 45 50 57 62 71
Working pressure (bar) 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6
Minimum burner head length (mm) 185 185 185 225 225 225 240 240 242 240 245 245 281 281 301 301 306
Expansion vessel connection (") 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 1 1/4 2 2 2 2 3 3 3 4 4 5
Return connection (DN) 50 50 50 50 65 65 65 65 80 80 100 100 125 125 150 150 200
Impulse connection (DN) 50 50 50 50 65 65 65 65 80 80 100 100 125 125 150 150 200
Ench./exhaustion (") 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 11/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2
Condensate output (") 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Weight without burner (kg) 335 340 415 440 530 560 655 855 1075 1210 1710 2085 2510 2930 3840 4605 5535
Ecoflam burner (not supplied)
Diesel (1 step) MAX 8 MAX 8 MAX 12 MAX 15 MAX 15 MAX 20 MAX 30 --- --- --- --- --- --- --- --- --- ---
Diesel (2 tiers) --- --- MAX P 12 AB HS MAX P 15 AB HS MAX P 15 AB HS MAX P 25 AB HS MAX P 25 AB HS MAX P 35 AB MAX P 45 AB MAJOR P 60 AB MAJOR P 80 AB MAJOR P 80 AB MAJOR P 120 AB MAIOR P 150.1 AB MAIOR P 200.1 AB MAIOR P 200.1 AB MAIOR P 300.1 AB
Diesel (modulating) --- --- --- --- --- --- --- MAIOR P 45 PR MAIOR P 45 PR MAIOR P 60 PR MAIOR P 80 PR MAIOR P 80 PR MAIOR P 120 PR MAIOR P 150.1 PR MAIOR P 200.1 PR MAIOR P 200.1 PR MAIOR P 300.1 PR
Gas (1 step) MAX GAS 105 P MAX GAS 105 P MAX GAS 120 P MAX GAS 170 P MAX GAS 250 P MAX GAS 250 P MAX GAS 350 P MAX GAS 500 P MAX GAS 500 P --- --- --- --- --- --- --- ---
Gas (2 tiers) MAX GAS 120 PAB MAX GAS 120 PAB MAX GAS 120 PAB MAX GAS 170 PAB MAX GAS 250 PAB MAX GAS 250 PAB MAX GAS 350 PAB MAX GAS 500 PAB MAX GAS 500 PAB BLU 700.1 LN PAB BLU 1000.1 LN PAB BLU 1200.1 LN PAB BLU 1500.1 LN PAB BLU 1500.1 LN PAB BLU 2000.1 LN PAB BLU 3000.1 LN PAB BLU 3000.1 LN PAB
Gas (modulating) --- --- --- --- --- --- MAX GAS 350 PR MAX GAS 500 PR MAX GAS 500 PR BLU 700.1 LN PR BLU 1000.1 LN PR BLU 1200.1 LN PR BLU 1500.1 LN PR BLU 1500.1 LN PR BLU 2000.1 LN PR BLU 3000.1 LN PR BLU 3000.1 LN PR